Principle
The "Henry" law of gas dissolution states that the dissolved oxygen gas in water is proportional to its proper pressure on the liquid surface (at the same time, it is related to the temperature of the water). As the water temperature increases, the solubility of the gas in the water decreases. When the water temperature reaches the boiling point, the water no longer has the ability to dissolve the gas. At this time, the vapor pressure on the water surface is equal to the external pressure, and the gas partial pressure is zero, and the gas cannot be dissolved in the water. According to this principle, the deaerator atomizes the water and heats it to 104°C in full contact with steam through a special filler, so that the dissolved gas escapes from the water.

Main process parameters
Working pressure and temperature: 0.02MPa 104℃
Soft water pressure and temperature: 0.2 MPa >20℃
Steam pressure and temperature: 0.33 MPa 145℃
Normal effluent oxygen content: ≤0.03mg/L
Safety valve take-off pressure: 0.06 MPa
Instructions for use
High-position deaerator
First, check the pressure gauge, temperature gauge, safety valve (take-off pressure 0.06 Mpa) and other control instruments until they are qualified.
Start the soft water pump, the water is fed through the soft water bypass valve, stop the pump after the liquid level of the water tank of the deaerator is normal, and turn on the secondary steam to make the water temperature of the water tank reach 100 ℃.
Open the exhaust valve at the top of the deaerator head (one-quarter to one-half opening), and open the soft water and steam bypass manual valves respectively. When the overflow water seal overflows and the water temperature reaches 104 °C, open the water outlet valve. At the same time start the boiler feed pump. (If the boiler is not in operation, all the feed water can be returned to the deaerator tank for a cycle test)
After the above manual operation experience checks that everything is normal, you can switch to automatic operation.
When the equipment is out of use, the water should be drained, the interior should be checked, the interior should be cleaned regularly and the interior should be brushed with varnish.
Device parameters
     Model
Item
KP10
KP20
KP35
KP50
KP70
KP100
KP150
Maximum output (T/H)
11
twenty two
40
56
78
106
160
Tank volume (m 3 )
6.4
12
20
30
40
40
50
Diameter of deaerator head Φ
600
800
1000
1200
1400
1500
1600
Diameter of water tankΦ
1600
2000
2400
2800
3000
3000
3000
L1
5000
5500
6000
6500
8250
8250
8600
L2
1900
2300
2700
3100
3300
3300
3300
L3
3800
4200
4600
5800
6500
6680
6820
F
1850
3150
2200
2860
3162
3162
3250
G
500
550
610
780
980
1090
1150
Z
1100
1200
1700
1700
1726
1726
1726
A
350
400
400
450
450
450
450
B
1400
1800
2200
2600
2600
2650
2650
C exhaust
1200
1400
1500
1600
1750
1755
1850
Exhaust DN1
40
40
50
50
80
80
80
Condensate into DN2
40
40
50
50
80
80
100
Make-up water into DN3
80
80
100
125
150
150
150
Steam into DN4
100
150
150
150
200
200
200
Feed pump return DN5
80
80
100
125
150
200
200
Steam balance DN6
100
125
150
150
200
200
200
Water outlet DN7
100
125
150
150
200
200
200
Secondary steam DN8
50
65
80
100
100
100
150
Water tank drain DN9
65
65
80
100
100
100
150
Water balance DN10
100
125
150
200
200
200
200