Thermal spray deaerator

Hotline
Principle
The "Henry" law of gas dissolution states that the dissolved oxygen gas in water is proportional to its proper pressure on the liquid surface (at the same time, it is related to the temperature of the water). As the water temperature increases, the solubility of the gas in the water decreases. When the water temperature reaches the boiling point, the water no longer has the ability to dissolve the gas. At this time, the vapor pressure on the water surface is equal to the external pressure, and the gas partial pressure is zero, and the gas cannot be dissolved in the water. According to this principle, the deaerator atomizes the water and heats it to 104°C in full contact with steam through a special filler, so that the dissolved gas escapes from the water.
Model
Item
|
KP10
|
KP20
|
KP35
|
KP50
|
KP70
|
KP100
|
KP150
|
Maximum output (T/H)
|
11
|
twenty two
|
40
|
56
|
78
|
106
|
160
|
Tank volume (m 3 )
|
6.4
|
12
|
20
|
30
|
40
|
40
|
50
|
Diameter of deaerator head Φ
|
600
|
800
|
1000
|
1200
|
1400
|
1500
|
1600
|
Diameter of water tankΦ
|
1600
|
2000
|
2400
|
2800
|
3000
|
3000
|
3000
|
L1
|
5000
|
5500
|
6000
|
6500
|
8250
|
8250
|
8600
|
L2
|
1900
|
2300
|
2700
|
3100
|
3300
|
3300
|
3300
|
L3
|
3800
|
4200
|
4600
|
5800
|
6500
|
6680
|
6820
|
F
|
1850
|
3150
|
2200
|
2860
|
3162
|
3162
|
3250
|
G
|
500
|
550
|
610
|
780
|
980
|
1090
|
1150
|
Z
|
1100
|
1200
|
1700
|
1700
|
1726
|
1726
|
1726
|
A
|
350
|
400
|
400
|
450
|
450
|
450
|
450
|
B
|
1400
|
1800
|
2200
|
2600
|
2600
|
2650
|
2650
|
C exhaust
|
1200
|
1400
|
1500
|
1600
|
1750
|
1755
|
1850
|
Exhaust DN1
|
40
|
40
|
50
|
50
|
80
|
80
|
80
|
Condensate into DN2
|
40
|
40
|
50
|
50
|
80
|
80
|
100
|
Make-up water into DN3
|
80
|
80
|
100
|
125
|
150
|
150
|
150
|
Steam into DN4
|
100
|
150
|
150
|
150
|
200
|
200
|
200
|
Feed pump return DN5
|
80
|
80
|
100
|
125
|
150
|
200
|
200
|
Steam balance DN6
|
100
|
125
|
150
|
150
|
200
|
200
|
200
|
Water outlet DN7
|
100
|
125
|
150
|
150
|
200
|
200
|
200
|
Secondary steam DN8
|
50
|
65
|
80
|
100
|
100
|
100
|
150
|
Water tank drain DN9
|
65
|
65
|
80
|
100
|
100
|
100
|
150
|
Water balance DN10
|
100
|
125
|
150
|
200
|
200
|
200
|
200
|